{"product_id":"cyberpower-online-s-premium-smart-app-ups-systems-6000va-5400w","title":"CyberPower Online S Premium Smart App UPS 6000VA 5400W","description":"\u003ch1\u003eCyberPower Online S (Premium) Smart App UPS Systems 6000VA 5400W\u003c\/h1\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cspan style=\"color: #993300;\"\u003eNote: Technology Products May Be Subject To Additional Fraud Checks By The Mega Team\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eCyberPower OLS6000E is a high-performance UPS featuring online double-conversion topology, which provides seamless Pure Sine Wave power for mission-critical devices such as NAS and servers, DVRs\/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment.\u003c\/p\u003e\n\u003cp\u003eSelected product is equipped with a Maintenance Bypass Switch. By flipping the switch, the power supply is safely transferred to utility. This allows service personnel to carry out fast on-site maintenance without having to shut down any connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOnline (Double Conversion) UPS Topology\u003c\/li\u003e\n\u003cli\u003eGenerator Compatible\u003c\/li\u003e\n\u003cli\u003eMaintenance Bypass Switch\u003c\/li\u003e\n\u003cli\u003eSmart Battery Management (SBM)\u003c\/li\u003e\n\u003cli\u003eSurge and Spike Protection\u003c\/li\u003e\n\u003cli\u003eLCD Status Display\u003c\/li\u003e\n\u003cli\u003ePowerPanel Management Software\u003c\/li\u003e\n\u003cli\u003eECO Mode\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eZero Transfer Time\u003c\/li\u003e\n\u003cli\u003eExtended Battery Module (EBM)\u003c\/li\u003e\n\u003cli\u003eEMI and RFI Filtration\u003c\/li\u003e\n\u003cli\u003eEmergency Power Off (EPO) Port\u003c\/li\u003e\n\u003cli\u003eSNMP\/HTTP Remote Management Capability (Optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the box:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eOLS6000E UPS\u003c\/li\u003e\n\u003cli\u003eParallel Port Cover Plate\u003c\/li\u003e\n\u003cli\u003eTerminal Cove\u003c\/li\u003e\n\u003cli\u003erTerminal Splices\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cem\u003e* Product contents may vary according to different regions. For detailed information, please refer to user's manual\/quick start guide.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cyberpower.com\/au\/en\/File\/GetCyberpowerFileByDocId\/DS-23070005-01\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Topology\u003c\/td\u003e\n\u003ctd\u003eOnline Double Conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Saving Technology\u003c\/td\u003e\n\u003ctd\u003eOnline ECO Mode Efficiency \u0026gt; 96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive PFC Compatibility\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Compatibility\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage ( Vac )\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range ( Vac )\u003c\/td\u003e\n\u003ctd\u003e110 ~ 276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAdjustable Voltage Range ( Vac )\u003c\/td\u003e\n\u003ctd\u003e0~80% Load for 110 ~ 276 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0~100% Load for 176 ~ 276 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eInput Frequency ( Hz )\u003c\/td\u003e\n\u003ctd\u003e50 ± 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 ± 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Detection\u003c\/td\u003e\n\u003ctd\u003eAuto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current ( A )\u003c\/td\u003e\n\u003ctd\u003e27.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector Type\u003c\/td\u003e\n\u003ctd\u003eHardwire Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (VA)\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (Watts)\u003c\/td\u003e\n\u003ctd\u003e5400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn Battery Waveform\u003c\/td\u003e\n\u003ctd\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOn Battery Voltage(s) ( Vac )\u003c\/td\u003e\n\u003ctd\u003e208 ± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220 ± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230 ± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 ± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Setting\u003c\/td\u003e\n\u003ctd\u003eConfigurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOn Battery Frequency ( Hz )\u003c\/td\u003e\n\u003ctd\u003e50 ± 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 ± 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Setting\u003c\/td\u003e\n\u003ctd\u003eConfigurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO Mode Voltage Tolerance\u003c\/td\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eInternal Current Limiting, Circuit Breaker, Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection (Line Mode)\u003c\/td\u003e\n\u003ctd\u003e105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, \u0026gt;170% Load for 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection (Battery Mode)\u003c\/td\u003e\n\u003ctd\u003e105~125% Load for 2 min, 125~150% Load for 30 sec, \u0026gt;150% Load for 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection (Bypass Mode)\u003c\/td\u003e\n\u003ctd\u003e125~150% Load for 1 min, 150~170% Load for 10 sec, \u0026gt;170% Load for 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e3:01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion (Linear Load)\u003c\/td\u003e\n\u003ctd\u003eTHD＜2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Distortion (Non-linear Load)\u003c\/td\u003e\n\u003ctd\u003eTHD＜5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic Bypass, Manual Bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Bypass\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet(s) - Total\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Type\u003c\/td\u003e\n\u003ctd\u003eHardwire Terminal Block x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Transfer Time ( ms )\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load ( min )\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load ( min )\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time ( Hours )\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Charging Current ( A )\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart On Battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Battery Management (SBM)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-replaceable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed Lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Extended Battery Module (EBM)\u003c\/td\u003e\n\u003ctd\u003eBPSE240V47A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. EBM Quantity ( pcs )\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSurge Protection \u0026amp; Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Suppression ( Joules )\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Filtration\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eManagement \u0026amp; Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Panel\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Information Display\u003c\/td\u003e\n\u003ctd\u003eOperation Type, Power Status, Battery Status, Load Status, Fault \u0026amp; Warning, Other Information, Event \u0026amp; Log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD Setting \u0026amp; Control\u003c\/td\u003e\n\u003ctd\u003eMode Setting, Alarm Setting, Input \u0026amp; Output, Battery Setting, Fault \u0026amp; Warning, Communication, Event \u0026amp; Log, Security Setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eLine Mode, Battery Mode, Bypass Mode, UPS Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHID Compliant USB Port(s)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Contact (with Relay)\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO) Port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eBattery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Cable ( pcs )\u003c\/td\u003e\n\u003ctd\u003eUSB Cable x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Management Software\u003c\/td\u003e\n\u003ctd\u003ePowerPanel Business (Recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSNMP\/HTTP Remote Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes - with optional RMCARD205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Construction\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePhysical Size - UPS Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD) (in.)\u003c\/td\u003e\n\u003ctd\u003e10.24 x 27.87 x 21.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD) (mm.)\u003c\/td\u003e\n\u003ctd\u003e260 x 708 x 550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (lbs.)\u003c\/td\u003e\n\u003ctd\u003e154.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg.)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD) (in.)\u003c\/td\u003e\n\u003ctd\u003e16.85 x 38.18 x 28.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxHxD) (mm.)\u003c\/td\u003e\n\u003ctd\u003e428 x 970 x 720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (lbs.)\u003c\/td\u003e\n\u003ctd\u003e180.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg.)\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°F)\u003c\/td\u003e\n\u003ctd\u003e32 ~ 104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity (Non-condensing) ( % )\u003c\/td\u003e\n\u003ctd\u003e0 ~ 95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation ( feet\/meters )\u003c\/td\u003e\n\u003ctd\u003e≤1000, Load Derated 1% per 100m from 1000m and 2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature (°F)\u003c\/td\u003e\n\u003ctd\u003e5 ~ 113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e-15 ~ 45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Relative Humidity (Non-condensing) ( % )\u003c\/td\u003e\n\u003ctd\u003e0 ~ 95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation ( feet\/meters )\u003c\/td\u003e\n\u003ctd\u003e0-49,213 feet (0-15,000 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnline Thermal Dissipation ( BTU\/hr )\u003c\/td\u003e\n\u003ctd\u003e1603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise at 1.5M from Surface of Unit ( dBA )\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Warranty Period (Year)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Warranty Period (Year)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAbout CyberPower\u003c\/h3\u003e\n\u003cp\u003eFounded in 1997, CyberPower has followed a path to success through engineering excellence and quality standards in power protection and computer accessories. At our advanced technology manufacturing facilities, we build a comprehensive line of power protection products, including Uninterruptible Power Supplies (UPS), Racks, Power Distribution Units (PDUs), Power Inverters, Surge Protectors, Mobile Chargers, power management software and computer peripheral accessories. After years of implementation of a global branding strategy, what we’ve provided to millions of satisfied customers are not only award-winning products, but a sense of security.\u003c\/p\u003e\n\u003cp\u003eWhether you are an IT professional working in a corporate data center, an owner of a small-to-medium business, or a consumer using electronic devices at home, CyberPower has a wide range of power solutions to safeguard your critical equipment and valued data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCHALLENGE\u003c\/strong\u003e\u003cbr\u003eThe world is changing and shifting rapidly. To continue to thrive over the next 10 years and beyond, we learn from the past, understand what may affect or shape our business in the future, identify new opportunities and continuously adapt to changing situations and competitive markets. These all form the backbones of our vision and mission of being a professional power solutions provider.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOUR VISION\u003c\/strong\u003e\u003cbr\u003eTo be a professional power solutions provider, delivering innovative and intelligent products to the customers while enhancing contributions to the environment preservation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOUR MISSION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDrive engineering excellence for high performance products\u003c\/li\u003e\n\u003cli\u003eCreate maximum values and profitability for customers and partners\u003c\/li\u003e\n\u003cli\u003eContribute to a greener environment and more caring society\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CyberPower","offers":[{"title":"Default Title","offer_id":53207710499179,"sku":"DSOLS6000E","price":3399.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/2795\/8891\/files\/cyberpower_online_s_premium_smart_app_ups_systems_6000va_5400w__89577.1697992476.500.750.png?v=1778474351","url":"https:\/\/megaofficesupplies.com.au\/products\/cyberpower-online-s-premium-smart-app-ups-systems-6000va-5400w","provider":"Mega Office Supplies","version":"1.0","type":"link"}